First check all the items in Error screen: Spindle Heath Check have been addressed.

Check which model of spindle you are using and which you have selected in the software. If you have selected that you are using an SC1 Spindle Motor in the maintenance app (see this article) SmartBench will register a Spindle Motor overload if you plug an SC2 Spindle Motor in.

If that doesn’t resolve the issue, please see this article to check your spindle motor for potential causes for overload.

 