< Previous | List | Next >
The extractor is an essential part of the SmartBench system, as it removes swarf during the machining process. This is necessary to make sure the job runs smoothly and safely. Build up of swarf on the workpiece can result in high levels of friction and heat at the cutting site. To prevent this, it is critical that swarf is removed from the cutting site during the job, using effective extraction. If appropriate extraction is not used, the build-up of swarf can force SmartBench out of position while it is cutting. This can cause job failure.
Overview for SmartBench v1.2
The extractor can be powered either from:
-
SmartBench, or
-
a separate power outlet
Powering your extractor from SmartBench is useful, since SmartBench can then automatically switch the extractor on and off.
However, the power supply cable to your SmartBench (shown above in red) may not be able to carry the extra load of the extractor. This depends on:
|
If your power supply cable to SmartBench is unable to support the extra load of your extractor, your extractor will need to be powered from a separate power outlet.
|
How to know if SmartBench can power your extractor
Step 1: Check your extractor power rating
Look for the extractor power rating specified by the manufacturer, and make a note of it. This should be stated on the electrical specification label found on the extractor itself.
For example, the extractor shown here has the power rating of 1200 W:
Step 2: Identify what voltage your SmartBench uses
Make a note of this value as well. Click here if you are not sure how to check what voltage your SmartBench uses.
The SmartBench in this image uses a 230 V input:
Step 3: Check your power supply cable region
If you are using the standard power cable supplied with SmartBench plugged into a mains outlet, you just need to know which geographical region it's for (most likely, the region you’re currently in).
If you are using a custom set up to power SmartBench, you will need to make a note of the current rating for your specific power cable or set up.
Step 4: Identify the maximum Extraction power allowed for your setup
Simply use the values from the previous steps, in this lookup table, to identify how much power is available for your extractor:
|
Maximum power (W) available for an extractor, if powered from SmartBench
|
Power cable region
|
120V SmartBench
|
230V SmartBench
|
UK
|
149
|
1578
|
USA/Can
|
389
|
2038
|
EU
|
509
|
2268
|
Aus/NZ
|
389
|
2038
|
If your extractor power is LESS than the identified capacity, you can power it through SmartBench.
If the extractor power is MORE than the identified capacity, you must power it separately (externally).
Worked example 1: An example workshop in the USA
For a particular workshop in the USA:
The table says this workshop could use an extractor up to 389 W.
|
Maximum power (W) available for an extractor, if powered from SmartBench
|
Power cable region
|
120V SmartBench
|
230V SmartBench
|
UK
|
149
|
1578
|
USA/Can
|
389
|
2038
|
EU
|
509
|
2268
|
Aus/NZ
|
389
|
2038
|
Since the extractor is 1200 W, it will draw too much current from SmartBench’s extraction power outlet. It will therefore need to be powered by an external source.
Worked example 2: An example workshop in the UK
For a particular workshop in the UK:
The table says this workshop could use an extractor up to 1578 W.
|
Maximum power (W) available for an extractor, if powered from SmartBench
|
Power cable region
|
120V SmartBench
|
230V SmartBench
|
UK
|
149
|
1578
|
USA/Can
|
389
|
2038
|
EU
|
509
|
2268
|
Aus/NZ
|
389
|
2038
|
Since the extractor is 1200 W, it is within the limit of what we can power from this SmartBench setup, so the extractor can be powered through SmartBench.
If you powering your extractor through SmartBench...
Connect the supplied power extension to the power outlet socket in the lower X beam.
If you powering your extractor externally...
Your extractor and SmartBench will need to be plugged into different external sources.
This is the wiring diagram:
A: Extractor power cable
B: SmartBench power cable
< Previous | List | Next >
Appendix A: Supplied SmartBench power cable ratings
This is the current rating for your supplied power cable, depending on your region:
UK
|
13 A
|
USA/Can
|
15 A
|
EU
|
16 A
|
Aus/NZ
|
15 A
|
Appendix B: How to calculate power requirements
In the following equations and examples, we are looking to work out the maximum power remaining for extraction, which is measured in Watts (W).
In order for SmartBench to be able to power the extractor, the extractor power rating has to be less than the maximum power remaining for extraction. If it is not, the extractor will need to be powered by an external source.
Assume that all currents input into our calculation are measured in Amps (A), and any voltages are measured in Volts (V).
Equation for a 120V SmartBench
(power cable current rating - 11.76) x 120 = maximum power remaining for extraction
Equation for a 230V SmartBench
(power cable current rating - 6.14) x 230 = maximum power remaining for extraction
Worked examples
Worked example 1: A particular workshop in the USA
For a particular workshop in the USA:
We’ll choose the equation for a 120V SmartBench:
(power cable current rating - 11.76) x 120 = maximum power remaining for extraction
We’ll plug our numbers into our equation:
maximum power remaining for extraction = (15 - 11.76) x 120
Do the calculation inside the brackets, (15 - 11.76 = 3.24):
maximum power remaining for extraction = (3.24) x 120
Do the final multiplication:
maximum power remaining for extraction = 388 W
Now, we can compare the maximum power remaining for extraction to the actual power rating of our extractor:
maximum power remaining for extraction = 388 W
extractor power rating = 1200 W
extractor power rating > maximum power remaining for extraction
The extractor uses more power than SmartBench can supply, so we’ll need to connect it to an external supply. Click here to learn more about this.
Worked example 2: A particular workshop in the UK
For a particular workshop in the UK:
We’ll choose the equation for a 230V SmartBench:
(power cable current rating - 6.14) x 230 = maximum power remaining for extraction
We’ll plug our numbers into our equation:
maximum power remaining for extraction = (13 - 6.14) * 230
Do the calculation inside the brackets, (13 - 6.14 = 6.86):
maximum power remaining for extraction = (6.86) * 230
Do the final multiplication:
maximum power remaining for extraction = 1600 W
Now, we can compare the maximum power remaining for extraction to the actual power rating of our extractor:
maximum power remaining for extraction = 1600 W
extractor power rating = 1200 W
extractor power rating < maximum power remaining for extraction
The extractor uses less power than SmartBench has available, so we can power the extractor directly from SmartBench. Click here to learn more about this.
< Previous | List | Next >